POST-TENSIONING SAS 950 / 1050 - Ø 26.5 to 47 mm SAS 835 / 1035 - Ø 57 to 75 mm |
|
The SAS 950 post-tensioning bars are available in diameter 26.5mm to 75mm. Associated with a complete range of nuts, couplers, plates, and others accessories, these bars can be used for temporary or permanent post-tensioning applications. The bars of diameter 26.5 to 40mm are approved to the European Technical Agreement N° 05/0122. In geotechnical applications, these bars can be used as active or passive tie rod anchors. |

|
1 rue Jacques Robert 95500 LE THILLAY FRANCE |


|
Deviator support |
|
Transverse Post-tensioning |
|
European Technical Agreement ETA-05/0122 |
|
Data Table |
|
European Technical Agreement |

|
Re / Rm |
Ø nominal |
Yield Point |
Breaking load |
Section |
Weight |
Elongation |
Elongation |
|
[N/mm²] |
[mm] |
[kN] |
[kN] |
[mm²] |
[kg/m] |
[%] |
[%] |
|
950 / 1050 |
26,5 |
525 |
580 |
551 |
4,48 |
5 |
7 |
|
950 / 1050 |
32 |
760 |
845 |
804 |
6,53 |
5 |
7 |
|
950 / 1050 |
36 |
960 |
1070 |
1020 |
8,27 |
5 |
7 |
|
950 / 1050 |
40 |
1190 |
1320 |
1257 |
10,21 |
5 |
7 |
|
950 / 1050 |
47 |
1650 |
1820 |
1735 |
14,10 |
5 |
7 |
|
835 / 1035 |
57 |
2155 |
2671 |
2581 |
20,95 |
4 |
7 |
|
835 / 1035 |
65 |
2780 |
3447 |
3331 |
27,10 |
4 |
7 |
|
835 / 1035 |
75 |
3690 |
4572 |
4418 |
35,89 |
4 |
7 |